← All topics

Electrode potentials and cells 电极电势与原电池

Choose a half-cell for each beaker. Your two half-cells are the blue dots on the E° scale and the orange arrow is E°cell. Watch which electrode becomes positive and which way the electrons go.

Predict first: zinc (−0.76 V) and silver (+0.80 V). The silver half-equation has to be doubled to balance the electrons. Is E°cell 1.56 V or 2.36 V? Decide, then choose Ag⁺/Ag for the right beaker.

Half-cell 半电池E° / VLeftRight

E°cell, standard cell potential

Positive (cathode)
Negative (anode)
Electrons (wire)
Ions (salt bridge)

About this model

E° values are from the CAIE 9701 data booklet (2025–2027 syllabus, section 4, 298 K). Other data booklets can differ by 0.01–0.02 V. The booklet gives no state symbols for Br₂ and I₂; they are written here as (aq), as in a cell. All solutions are 1.00 mol dm⁻³, gases are at 100 kPa and the temperature is 298 K.

The cell is schematic. The salt bridge is filter paper or a tube soaked in KNO₃(aq); KCl is avoided with Ag⁺ because AgCl would precipitate. The H⁺/H₂ and Cl₂/Cl⁻ electrodes are platinum (platinised for hydrogen) with gas bubbled over them; Pt is also used when both species are ions (Fe³⁺/Fe²⁺, MnO₄⁻/Mn²⁺). A high-resistance voltmeter draws almost no current, so it measures E°cell; the moving electrons show the direction of flow when the cell supplies a current.

Key idea

  • The half-cell with the more positive E° is the positive electrode: reduction happens there (cathode).
  • E°cell = E°(positive) − E°(negative), so it is always positive for the working cell.
  • Electrons flow through the external wire from the negative electrode to the positive electrode.

MistakeCommon mistake 常见错误

  • “Ag⁺ + e⁻ is doubled, so use 2 × 0.80.” → No mark. Say: E° is not multiplied by the coefficient: +0.80 − (−0.76) = +1.56 V.
  • “Electrons flow through the salt bridge.” → No mark. Say: electrons flow through the external circuit; ions move through the salt bridge to complete the circuit.
  • “Zn has the more negative E°, so it is the cathode.” → No. Say: it is the negative electrode, where oxidation happens (anode).

Feasible? 反应可行性

  • E°cell > 0 for a reaction as written: it is feasible. The reverse reaction has the same value with a negative sign, so it is not.
  • Feasible does not mean fast: a large activation energy can make it too slow to see.
  • E° applies only under standard conditions; changing concentration changes E.

Check yourself

Exam-style question[1]

A cell is made from a Ni²⁺/Ni half-cell (E° = −0.25 V) and an Ag⁺/Ag half-cell (E° = +0.80 V). Which statement is correct?

Where this is in your course

7 courses: CAIE, Edexcel IAL and A Level, AQA, OxfordAQA, AP, IB
CourseTopic
CAIE A Level 9701 (2025–27)A Level 24.2 Standard electrode potentials E°, standard cell potentials E°cell and the Nernst equation: outcomes 1–7 (definitions, SHE, E°cell, polarity and electron flow, feasibility, oxidising and reducing agents, redox equations); 8–9 Nernst equation; 10 ΔG° = −nE°cellF
Edexcel IAL (WCH15)Unit 5, Topic 16 Redox Equilibria: 16.2–16.5 (E°, SHE), 16.7 (E°cell), 16.8 (cell diagrams), 16.10 (feasibility), 16.11 (E°cell, ΔStotal and ln K), 16.12 (limitations), 16.13 (electrochemical series)
Edexcel A Level (9CH0)Topic 14 Redox II: points 3–5 (E°, SHE), 7 (E°cell), 8 (cell diagrams), 10 (feasibility), 11 (E°cell, ΔStotal and ln K), 12 (limitations), 13 (electrochemical series)
AQA A Level 74053.1.11.1 Electrode potentials and cells (A-level only)
OxfordAQA International A Level (9620)3.1.9.1 Electrode potentials and cells (International A2)
AP Chemistry (CED 2024)Unit 9, Topic 9.8 Galvanic (Voltaic) and Electrolytic Cells; 9.9 Cell Potential and Free Energy; 9.10 Cell Potential Under Nonstandard Conditions
IB Chemistry (first assessment 2025)Reactivity 3.2.5–3.2.6 (anode and cathode, primary cells, electron flow, salt bridge: SL and HL); HL: 3.2.12 (SHE, E°), 3.2.13 (E°cell, spontaneity), 3.2.14 (ΔG° = −nFE°cell)

Numbers checked against the specification PDFs in the specs folder (CAIE 2025–27, Edexcel IAL 2018 edition, Edexcel A Level issue 2, AQA 7405 v1.1, OxfordAQA v5.0, AP CED effective Fall 2024, IB guide 2023).

Course differences

What is extra or not required in each course
  • IB SL: only the voltaic cell itself: anode and cathode, electron flow and salt bridge (Reactivity 3.2.5–3.2.6). E° values, E°cell and ΔG° = −nFE°cell are HL (3.2.12–3.2.14).
  • AP: uses anode and cathode; labelling an electrode positive or negative is not assessed (9.8.A.3). E°cell is calculated from the reduction and oxidation half-reactions (9.9.A.2).
  • ΔG° = −nFE°cell: CAIE (24.2.10), AP (9.9) and IB HL (3.2.14). Edexcel instead links E°cell to ΔStotal and ln K. Not in AQA or OxfordAQA.
  • Nernst equation: CAIE uses it in calculations (24.2.9). AP treats non-standard conditions qualitatively (9.10). AQA and OxfordAQA say “Nernst equation not required”; Edexcel asks only why conditions matter (16.9 / 9CH0 point 9).
  • Cell diagrams (e.g. Zn(s) | Zn²⁺(aq) ‖ Cu²⁺(aq) | Cu(s), with E°cell = E°right − E°left): Edexcel IAL and A Level, AQA and OxfordAQA. Not listed for CAIE, AP or IB.
  • Edexcel: limitations of E° predictions (kinetics and non-standard conditions) and disproportionation are named points (16.12, 16.14).
  • Commercial cells and fuel cells (AQA 3.1.11.2, OxfordAQA 3.1.9.2, Edexcel, IB 3.2.7) and electrolysis are not on this page.